Problem Possible Cause Solution
Compressor will not run Tank has sufficient pressure.
No electrical power.
Blown stop/house fuse.
Tripped shop/home breaker.
Thermal overload open.
Loss of power or overheating.
Pressure switch is bad.
Compressor will turn on when tank
pressure drops to cut-in pressure.
Check to be sure unit is plugged in.
Replace shop/house fuse.
Reset shop/home breaker, determine why
problem happened.
First unplugged the compressor and
wait until it becomes cool. After that
compressor can be used.
Check for proper use of extension cord.
Replace pressure switch.
Motor hums but cannot run or runs
slowly
Low voltage.
Wrong gauge wire or length of
extension cord.
Shorted or open motor winding.
Defective check valve or unloader.
Check with voltmeter.
Check for proper gauge wire and cord
length.
Take compressor to service center.
Take compressor to service center.
Fuses blow/circuit breaker trips
repeatedly
Incorrect size fuse, circuit overload.
Wrong gauge wire or length of
extension cord.
Defective check valve or unloader.
Check for proper fuse, use time-
delay fuse, disconnect other electrical
appliances from circuit or operate
compressor on its own branch circuit.
Check for proper gauge wire and cord
length.
Take compressor to service center.
Thermal overload protector cuts out
repeatedly
Low voltage.
Lack of proper ventilation/room
temperature too high.
Wrong gauge wire or length of
extension cord.
Check with voltmeter.
Move compressor to well-ventilated area.
Check for proper gauge wire and cord
length.
Air receiver pressure drops when
compressors shuts off
Loose connections (fittings, tubing,
etc.).
Loose drain valve.
Check valve leaking.
Check all connections with soap and
water solution and tighten.
Tighten drain valve.
Take compressor to service center.
Excessive moisture in discharge air Excessive water in air tank.
High humidity.
Drain tank.
Move to area of less humidity; use air line
filter.
Air leaking Loose or improperly sealed hose
connection.
Broken or damaged air hose.
Ensure connections are sealed with
thread sealing tape and tightened.
Replace air hose.
Compressor runs continuously Tank drain valve open.
Defective pressure switch.
Excessive usage.
Ensure tank drain valve is closed.
Take compressor to service center.
Decrease air usage; compressor not large
enough for tool’s requirement.
Compressor vibrates Loose mounting bolts. Tighten mounting bolts.
Air output lower than normal Broken inlet valves.
Connections leaking.
Take compressor to service center.
Apply thread sealing tape to fitting and
tighten.